home

Unità di trattamento aria packaged ad alta efficienza

e-eNeRGy

Ideale per i grandi spazi industriali aperti e magazzini, in particolare per i nuovi edifici, e-eNeRGy garantisce prestazioni ottimali e risparmio energetico. Adattabile per R32, soddisferà le tue esigenze e tutti i requisiti ambientali.

Kühlleistung

109 - 163 kW

Heizleistung

112 - 168 kW

Luftstrom

18900 - 27000 m3/h

+RedgeProductNomenclature +RedgeProductNomenclature.productRange_dotraw:e-energy

Modelbezeichnung

EE A 14 B A C H D 85 E F F

A EE = e-eNeRGy

B Luftdurchsatz (x 1000 m3/h)

C A = Luftgekühlte Verflüssigung

D H = Wärmepumpe – N = Kein Verflüssigungssatz

E Kühlleistung in kW

F F = Standard-Scrollverdichter

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load - kg
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  •  
  • E019AH110F
  • 4.35
  • 171
  • B
  •  
  • 3.31
  •  
  • 13000
  • 18900
  • 24000
  •  
  • 111.8
  • 33.1
  • -
  •  
  • 82 / 100
  • 36 / 108
  • 36 / 108
  • 74.5 / 132
  •  
  • 2
  • 4
  • 27.6
  •  
  • 108.6
  • 38.16
  •  
  • 56
  • 213.4
  • 93.9
  • 10
  •  
  • 82
  • 87.6
  •  
  • E024AH140F
  • 4.47
  • 175.8
  • B
  •  
  • 3.44
  •  
  • 17000
  • 24300
  • 32000
  •  
  • 142.4
  • 41.44
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 35.6
  •  
  • 138.7
  • 48.12
  •  
  • 73.5
  • 238.8
  • 117.6
  • 10
  •  
  • 84.2
  • 88.5
  •  
  • E027AH170F
  • 4.4
  • 173
  • B
  •  
  • 3.22
  •  
  • 18500
  • 27000
  • 32000
  •  
  • 167.9
  • 50.48
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 36
  •  
  • 163.4
  • 55.38
  •  
  • 83.6
  • 279.1
  • 134.7
  • 10
  •  
  • 84.9
  • 88.8

  1. Cooling capacity : Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating capacity : Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling Mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load - kg
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  •  
  • E019AH110F
  • 4.35
  • 171
  • B
  •  
  • 3.31
  •  
  • 13000
  • 18900
  • 24000
  •  
  • 111.8
  • 33.1
  • -
  •  
  • 82 / 100
  • 36 / 108
  • 36 / 108
  • 74.5 / 132
  •  
  • 2
  • 4
  • 27.6
  •  
  • 108.6
  • 38.16
  •  
  • 56
  • 213.4
  • 93.9
  • 10
  •  
  • 82
  • 87.6
  •  
  • E024AH140F
  • 4.47
  • 175.8
  • B
  •  
  • 3.44
  •  
  • 17000
  • 24300
  • 32000
  •  
  • 142.4
  • 41.44
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 35.6
  •  
  • 138.7
  • 48.12
  •  
  • 73.5
  • 238.8
  • 117.6
  • 10
  •  
  • 84.2
  • 88.5
  •  
  • E027AH170F
  • 4.4
  • 173
  • B
  •  
  • 3.22
  •  
  • 18500
  • 27000
  • 32000
  •  
  • 167.9
  • 50.48
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 36
  •  
  • 163.4
  • 55.38
  •  
  • 83.6
  • 279.1
  • 134.7
  • 10
  •  
  • 84.9
  • 88.8

  1. Cooling capacity : Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating capacity : Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling Mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

Soluzione packaged ad alta efficienza

Soluzione ecologica

e-eNeRGy è adattabile per R32, un refrigerante a basso GWP e ti aiuta a ridurre la tua impronta di carbonio; riducendo così le imposte ambientali e i costi operativi.

Concetto modulare

Adatta perfettamente il tuo sistema alle tue esigenze grazie a diverse configurazioni sulla direzione del flusso d'aria, oltre alla flessibilità in termini di capacità, avendo a disposizione diverse capacità per lo stesso flusso d'aria.

Funzionamento silenzioso

Sono disponibili diverse opzioni di attenuazione acustica per ridurre il livello di rumore durante il funzionamento.

Assistenza intelligente tramite Lennox Cloud

Le metriche e-eNeRGy sono accessibili 24 ore su 24 e 7 giorni su 7 tramite Lennox Cloud. Questo accesso remoto alla macchina ne consente il monitoraggio permanente e aiuta a prevedere le operazioni di manutenzione, offrendo una migliore reattività.

Eine Frage?

Kontaktieren Sie uns für weitere Informationen

Wenden Sie sich an Redge
Schwierigkeiten ?

Für Anfragen zur Nova stehen Ihnen unser technischer Support gerne zur Verfügung. e-eNeRGy

Wenden Sie sich an Redge

Produktressourcen und Dateien

Redge Service Catalogue

HVAC-Dienstleistungen

Holen Sie das Optimum aus Ihrer Ausrüstung heraus - mit der Unterstützung von Menschen, die diese genauestens kennen

Wartung

Rechtliche Unterstützung

System-Modernisierung

Systemoptimierung

Reparaturen

Ersatzteil

Sie suchen Unterstützung im Bereich der Dienstleistungen?

Sprechen Sie mit unserem After-Sales-Team und erhalten Sie alle Hilfe, die Sie für die Fehlerbehebung und Wartung Ihrer Redge-Geräte benötigen

Wenden Sie sich an Redge