home

Unità di trattamento aria packaged ad alta efficienza

e-eNeRGy

Ideale per i grandi spazi industriali aperti e magazzini, in particolare per i nuovi edifici, e-eNeRGy garantisce prestazioni ottimali e risparmio energetico. Adattabile per R32, soddisferà le tue esigenze e tutti i requisiti ambientali.

Cooling capacity

109 - 163 kW

Heating capacity

112 - 168 kW

Airflow capacity

18900 - 27000 m3/h

+RedgeProductNomenclature +RedgeProductNomenclature.productRange_dotraw:e-energy

Model Nomenclature

EE A 14 B A C H D 85 E F F

A EE = e-eNeRGy

B Airflow (x 1000 m3/h)

C A = Air cooled condensation

D H = Heat pump - N = No condensing unit

E Cooling capacity in kW

F F = Standard scroll compressor

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load - kg
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  •  
  • E019AH110F
  • 4.35
  • 171
  • B
  •  
  • 3.31
  •  
  • 13000
  • 18900
  • 24000
  •  
  • 111.8
  • 33.1
  • -
  •  
  • 82 / 100
  • 36 / 108
  • 36 / 108
  • 74.5 / 132
  •  
  • 2
  • 4
  • 27.6
  •  
  • 108.6
  • 38.16
  •  
  • 56
  • 213.4
  • 93.9
  • 10
  •  
  • 82
  • 87.6
  •  
  • E024AH140F
  • 4.47
  • 175.8
  • B
  •  
  • 3.44
  •  
  • 17000
  • 24300
  • 32000
  •  
  • 142.4
  • 41.44
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 35.6
  •  
  • 138.7
  • 48.12
  •  
  • 73.5
  • 238.8
  • 117.6
  • 10
  •  
  • 84.2
  • 88.5
  •  
  • E027AH170F
  • 4.4
  • 173
  • B
  •  
  • 3.22
  •  
  • 18500
  • 27000
  • 32000
  •  
  • 167.9
  • 50.48
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 36
  •  
  • 163.4
  • 55.38
  •  
  • 83.6
  • 279.1
  • 134.7
  • 10
  •  
  • 84.9
  • 88.8

  1. Cooling capacity : Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating capacity : Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling Mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

Model Specification

  • Seasonal Efficiencies Cooling Mode
  • Product Index
  • Seasonal Energy Efficiency Ratio - SEER
  • Seasonal Energy Efficiency
  • Eurovent Energy Efficiency Class Part Load Operation
  • Seasonal Efficiencies Heating Mode
  • Seasonal Coefficient Of Performance - SCOP
  • Ventilation Data
  • Minimum Airflow Rate - m³/h
  • Nominal Airflow Rate - m³/h
  • Maximum Airflow Rate - m³/h
  • Nominal Thermal Performance Heating
  • Heating Capacity - kW
  • Total Power Input - kW
  • Cop Net
  • Auxillary Heating
  • Gas heating capacity - Standard/High - kW
  • Electric heater capacity - Standard/High - kW
  • Electric pre-heater capacity - Standard/High - kW
  • Hot Water Coil Capacity Air Inlet Water
  • Refrigeration Circuit
  • Number Of Circuits
  • Number Of Compressors
  • Refrigerant Load - kg
  • Nominal Thermal Performance Cooling
  • Cooling Capacity - kW
  • Total Power Input - kW
  • Electrical Data
  • Maximum Power - kW
  • Maximum Current - A
  • Starting Current - A
  • Short Circuit Current - kA
  • Acoustic Data
  • Outdoor Sound Power Standard Unit - dB(A)
  • Indoor Blower Outlet Sound Power Standard Unit - dB(A)
  •  
  • E019AH110F
  • 4.35
  • 171
  • B
  •  
  • 3.31
  •  
  • 13000
  • 18900
  • 24000
  •  
  • 111.8
  • 33.1
  • -
  •  
  • 82 / 100
  • 36 / 108
  • 36 / 108
  • 74.5 / 132
  •  
  • 2
  • 4
  • 27.6
  •  
  • 108.6
  • 38.16
  •  
  • 56
  • 213.4
  • 93.9
  • 10
  •  
  • 82
  • 87.6
  •  
  • E024AH140F
  • 4.47
  • 175.8
  • B
  •  
  • 3.44
  •  
  • 17000
  • 24300
  • 32000
  •  
  • 142.4
  • 41.44
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 35.6
  •  
  • 138.7
  • 48.12
  •  
  • 73.5
  • 238.8
  • 117.6
  • 10
  •  
  • 84.2
  • 88.5
  •  
  • E027AH170F
  • 4.4
  • 173
  • B
  •  
  • 3.22
  •  
  • 18500
  • 27000
  • 32000
  •  
  • 167.9
  • 50.48
  • -
  •  
  • 100 / 200
  • 54 / 144
  • 54 / 144
  • 123.9 / 198.6
  •  
  • 2
  • 4
  • 36
  •  
  • 163.4
  • 55.38
  •  
  • 83.6
  • 279.1
  • 134.7
  • 10
  •  
  • 84.9
  • 88.8

  1. Cooling capacity : Cooling mode : According to EN14511 nominal conditions - Outdoor temperature 35°C DB - Indoor temperature 27°C DB / 19°C WB
  2. Heating capacity : Heating mode : According to EN14511 nominal conditions - Outdoor temperature 7°C DB / 6°C WB - Indoor temperature 20°C DB
  3. Seasonal Energy Efficiency Ratio - SEER : SEER in accordance with standard EN14825.
  4. Seasonal energy efficiency - Cooling Mode : Space cooling energy efficiency following Ecodesign regulation EU 2016/2281
  5. Seasonal Coefficient of Performance - SCOP : SCOP in accordance with standard EN 14825 (average climate conditions).
  6. Seasonal energy efficiency - Heating Mode : Space heating energy efficiency following Ecodesign regulation EU 2016/2281.

Soluzione packaged ad alta efficienza

Soluzione ecologica

e-eNeRGy è adattabile per R32, un refrigerante a basso GWP e ti aiuta a ridurre la tua impronta di carbonio; riducendo così le imposte ambientali e i costi operativi.

Concetto modulare

Adatta perfettamente il tuo sistema alle tue esigenze grazie a diverse configurazioni sulla direzione del flusso d'aria, oltre alla flessibilità in termini di capacità, avendo a disposizione diverse capacità per lo stesso flusso d'aria.

Funzionamento silenzioso

Sono disponibili diverse opzioni di attenuazione acustica per ridurre il livello di rumore durante il funzionamento.

Assistenza intelligente tramite Lennox Cloud

Le metriche e-eNeRGy sono accessibili 24 ore su 24 e 7 giorni su 7 tramite Lennox Cloud. Questo accesso remoto alla macchina ne consente il monitoraggio permanente e aiuta a prevedere le operazioni di manutenzione, offrendo una migliore reattività.

A question?

Contact us for more information

Contact Redge
Encountering difficulty?

Contact us for technical support on e-eNeRGy

Contact Redge

Product Resources and Files

Redge Service Catalogue

HVAC Services

Get the most out of the equipment with our service offering, from the people who know it best

Maintenance

Regulatory support

System's modernisation

System's optimisation

Repairs

Spare parts

Looking for service related support?

Talk to our service team and get all the help you need to troubleshoot and service your equipment.

Contact Redge